Tel :0086-577-27821888
Fax :0086-577-62781000
Email:bethy@tuanjie.com
MSN:bethy282@hotmail.com |
| |
 |
| |
|
 |
| Home
>> Product >> Switching
Power>> 100W Triple Output Switching
Power Supply (SKT-100) |
100W Triple Output
Switching Power Supply (SKT-100) |
|
|
Features:
-High efficiency, high reliability
-Universal AC input/full range
-100%full load burntest
-Protections: Short circuit/Over load
-Cooling by free air convection
-2 years warranty
-Dimensions: 19941>*110*50mm(L*W*H)
-Triple output high precision voltage |
SPECIFICATIONS
INPUT
Voltage Range |
85~132 VAC/170~264VAC47~63 Hz£»selected
by switch 240~370VDC |
AC Current |
2.5A/115V1.25A/ 230V |
Efficiency |
77%(SKT-100C); 79%(SKT-100D) |
Inrush Current |
Cold start 30A/115V60A/230V |
Leakage Current |
<0.5mA/240VAC |
OUTPUT
Model |
SKT-100C-CH1 |
SKT-100C-CH2 |
SKT-100C-CH3 |
SKT-100D-CH1 |
SKT-100D-CH2 |
SKT-100D-CH3 |
DC Voltage |
5V |
15V |
--15V |
5V |
12V |
24V |
Voltage Tolerance |
±2% |
±6% |
±6% |
±2% |
±6% |
±6% |
Rated Current |
10A |
2.5A |
1A |
6A |
2A |
2A |
Current Range |
212A |
0.22.5A |
0.11A |
2-12A |
0.12A |
0.22A |
Rated Power |
100W |
100W |
100W |
102W |
102W |
102W |
Ripple & Noise |
80mVp-p |
150 mVp-p |
150 mVp-p |
80 mVp-p |
150 mVp-p |
150 mVp-p |
DC Adjustment Range |
CH:+10,-5% |
|
|
|
|
|
Setup,Rise,Hold Time |
200ms,500ms,16ms |
|
|
|
|
|
PROTECTION
Over Load |
105%~150% |
| |
Protection type: Shut down o/p
voltage, re-power on to recover |
ENVIRONMENT
Working Temp., Humidity |
-10°C~+50°C, 20%~90 %RH |
Storage Temp., Humidity |
-20°C~+85°C, 10%~95 %RH |
Vibration |
10~500Hz, 2G 10min./1cycle, period
for 60min, each along X, Y, Z axes |
SAFETY
Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG:
0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 500VDC/100M
Ohm¸ |
STANDARD
Safety Standard |
Design refer to UL1012 |
EMC Standard |
Design refer to FCC PART15 J CONDUCTION
CLASS B |
OTHERS
Weight |
0.83Kg |
Packing |
16pcs/14.7Kg/0.95CUFT |
NOTE
1. All parameter
measured in 230V input voltage, rated load 25°C,
70% humidity. |
2. Tolerance: includes set up
tolerance, line regulation and load regulation |
3. Ripple & noise are measured
at 20MHz of bandwidth by using a 12"twisted pair-wire
terminated with a 0.1µ &47µ parallel
capacitor |
4. The line regulation is measured
at full load, input voltage from 85-264 VAC. |
5. The load regulation is measured
at 230VAC input voltage, and output current changed
from mini load to fullload,other ouput
is 60% rated load |
6. Each output can within current
range. But total output power can't exceed rated load |
|
| |
|
|