100W Single Output
Switching Power Supply (SKS-100T) |
|
|
Features:
-High efficiency, high reliability
-AC input range selected by switch
-100%full load burnin test
-Protections: Short circuit/Over load
-Cooling by free air convection
-Fixed switching frequency at 110KHz
-1 years warranty
-Dimensions: 159*97*38mm(L*W*H) |
SPECIFICATIONS
INPUT
| Voltage Range |
90~135VAC/180~264 VAC47~63Hz |
| AC Current |
1.9A/1151A/ 230 V |
| Efficiency |
78%(SKS-100T-5); 80%(SKS-100T-7.5); 81%(SKS-100T-12); 82%(SKS-100T-15);
84%(SKS-100T-24); 84%(SKS-100T-48); |
| Inrush Current |
Cold start 50A/230V |
| Leakage Current |
<1mA/240VAC |
OUTPUT
| Model |
SKS-100T-5 |
SKS-100T-7.5 |
SKS-100T-12 |
SKS-100T-15 |
SKS-100T-24 |
SKS-100T-48 |
| DC Voltage |
5V |
7.5V |
12V |
15V |
24V |
48V |
| Voltage Tolerance |
±1.5% |
±1.5% |
±1% |
±1% |
±1% |
±1% |
| Rated Current |
15A |
11A |
8.3A |
6.6A |
4.2A |
2.1A |
| Current Range |
015A |
011A |
08.3A |
06.6A |
04.2A |
02.1A |
| Rated Power |
75W |
82.5W |
99.6W |
99W |
100.8W |
100.8W |
| Ripple & Noise |
80mVp-p |
120 mVp-p |
120 mVp-p |
120 mVp-p |
150 mVp-p |
150 mVp-p |
| DC Adjustment Range |
±10% |
±10% |
±10% |
±10% |
±10% |
±10% |
| Setup,Rise,Hold Time |
300ms,150ms,20ms |
|
|
|
|
|
PROTECTION
| Over Load
|
115%~150%
Protection type: Fold back current limiting, auto-recovery |
ENVIRONMENT
| Working Temp., Humidity |
-10°C~+50°C, 20%~90
%RH |
| Storage Temp., Humidity |
-20°C~+85°C, 10%~95
%RH |
| Vibration |
10~500Hz, 2G 10min./1cycle,
period for 60min, each along X, Y, Z axes |
SAFETY
| Withstand Voltage |
I/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG:
0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M
Ohms/500VDC |
STANDARD
| Safety Standard |
Design refer to UL1012, EN60950 |
| EMC Standard |
Design refer to EN55022,
EN55024, EN61000, IEC801-2,3,4, IEC555-2 |
OTHERS
| Weight |
0.51Kg |
| Packing |
30pcs/16.1Kg/1.2CUFT |
NOTE
| 1.All parameters NOT specially
mentioned are measured at 230VAC input, rated load
and 25°C of ambient temperature. |
| 2.Ripple & noise are
measured at 20MHz of bandwidth by using a 12"twisted
pair-wire terminated with a 0.1µ &47µ
parallel capacitor. |
| 3.Tolerance: includes set
up tolerance, line regulation and load regulation |
| 4.The power supply is considered
a component which will be installed into a final
equipment. The final equipment must be re-confirmed
that it still meets EMC directives. |
|
| |
|
|